Get complete information related to latest Tape Changer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tape Changer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tape Changer Tenders.
Tender For supply of step down transformer 60 kva (delta to star) capacity- input voltage 750 volts out put 415 volt ac, 50 hz, housing and fitment of transformer is as per rdso spec.no. el/eog/6/93 (rev-a)-97. and rdso drg. no.- 4251 alt. 1. suitable for pow ac pantry coach. [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For supply of general electric items b b - wire 22swg , glass sleev 14 mm , slip ring for cane unloader bbl make 10 kw motor , exhaust fan 24 , plastic cooling fan for 5 00 hp motor , plastic cooling fan for 7 5 hp motor , plastic cooling fan for 10 hp motor , havells make auto cut hot air blower 2000 watt with overheat protection , soldering iron 65 watt , soldring wire , plastic cooling fan for 50 hp motor , teflon rod dia 65mm length 300mm , glass sleev 16 mm , mash rum type push button red , mash rum type push button blue , plastic cooling fan for 15 hp motor , carbon brush 12 20 32 , mettalic carbon brush 20 15 8 , carbon brush 30 20 100 , timer st 800 , carbon brush 21 31 37 , porcelean kit kat200 amp 415 v standard make , fuse wire 6 amp , fuse wire 10 amp , fuse wire 16 amp , dol starter empty box mk1 , dol starter empty box ml2 , exhaust fan 16 1 phase 960rpm ci body crompton havells make , carbon brush 20 32 40 , rocker arm 12 5 hp kec slip ring motor , h t connector 3 way , h t connector 6 way , potentio meter 500 ohm 2 w 10 turn bourns make , diode 6 amp , step down double phase transformer 415 vac to 24vdc , usha bajaj make room heater with ss reflector and body , dc solenoid coil for hydraulic grab for reverse forward direction , ss seamless ring size 1 for cane unloader , karam make industrial safety belt , silk rope 3 4 resham , foldable aluminium ladder 16 ft , amp meter 400 5 96 96 , amp meter 0 100 5 96 96 , amp meter 150 5 96 96 , limit switch 1 no 1 nc type ls 011 10 amp 500 v , frequency meter 96 96 , frequency meter digital type , air cooled resistance box for 12 5 hp 15 hp bbl make slipring motor , analog rpm meter make beacon sensor type input magnetic picup no of teeth 06 range 0 8000 rpm , selector switch for volt meter , selector switch for amp meter , volt meter 96 96 0 500 vac ae make , current transformer ct 250 5a , amp meter 300 5 96 96 , amp meter 600 5 96 96 , dyno pack with controller , current transformer ct 300 5a , current transformer ct 400 5a , current transformer ct 600 5a , current transformer ct 500 5a , current transformer ct 100 5a , carbon holder for 12 5 hp slip ring motor cane unloader motor , current transformer ct 500 1 a , amp meter 500 5 96 96 , amp meter 800 5 96 96 , porcelean kit kat 100 amp 415v , amp meter 250 5 96 96 , amp meter 1200 5 96 96 , timer 800 q 1 no 1 nc , portable single phase welding machine 220 vac , current transformer 1200 1 , current transformer 1200 5 , ictpn switch 200 amp , metravi make nctm 200 contact on contact combined digital tacho metermeter , diamond hammer drill bit size 6 mm for aluminium busbar drilling , diamond hammer drill bit size 8 mm for aluminium busbar drilling , diamond hammer drill bit size 10 mm for aluminium busbar drilling , diamond hammer drill bit size-14 mm for aluminium busbar drilling
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tapechanger in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)
Tender For appointment of contractor/bidder for supply of material, erection, testing & commissioning for augmentation of 72 nos. existing 33 kv sub-stations (including civil work as per site requirements) on turnkey basis under revamped reforms-based and results-linked distribution scheme- 33/11 kv s/stn. items , 12.5 mva threee phase 50 hz, 33/11 kv step down outdoor onan power transformer complete with all accessories/fittings and conforming to latest nigam's technical specification with amendments relevant iss with latest amendments., , 33kv l & e switch (630amps), , 33kv isolators (630 amps), , 33 kv vcb, 36 kv, 1250a with 1000 mva (16 ka for 1 second) rupturing capacity vcb for out door use conforming to latest nigam's technical specification no. csc-24/r-ii/uh/dh/p&d/2020-21 with relevant iss & latest amendments thereof., , 33 kv c&r panel 24 v dc operated suitable for controlling one t/fs (with differential protection) as per nigam's tech. spec., relevant iss and latest amendments., , 33kv lightening arrestor sub-stn type 30kv 10ka with surge counter., , 33kv cts 600/300/5-5-5-5 with junction box, , 33kv pts with junction box, , 33kv post insulators, , disc fitting t&c type, , 11 kv vcb rating 1250 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for incoming panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for outgoing panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for capacitor panel i/d type, , 11kv lightening arrestor sub-stn type 9 kv 10ka (heavy duty), , 11kv ncts 900/5a, , 11 kv automatically switched capacitor apfc capacitors panal 4.8 mvar complete (with l&e switch, structure and all allied material as per nigam's tech. spec., relevant iss and latest amendments, , structure for 33 kv cts (galvanized) wt. 87.62 kg., , structure for 33 kv pts (galvanized) wt. 87.62 kg., , structure for 33 kv la (galvanized) wt. 76.38 kg., , structure for 33 kv post insulators (galvanized) wt. 76.38 kg, , structure for 33 kv isolator (galvanized) wt.288.36 kg., , structure for l&e switch (galvanized) wt.288.36 kg., , structure for 11 kv nct (galvanized) wt.92.37 kg., , structure for cable stand, , gantry tower-2xdb-2, 2xdt-2, 2xdt-3 per sub-station, , structure for 11kv la/cable stand, , acsr conductor 80 sq mm(raccoon), , acsr conductor 0.2 sq in(panther), , 11kv single core xlpe cable 630mm², , 11 kv outdoor cable boxes for s/c 630 sq mm cable, , 11 kv indoor cable boxes for s/c 630 sq mm cable, , 11 kv xlpe cable 3 c x 300 sq. mm for capacitor bank, , 11 kv outdoor cable boxes for 3c x 300 sq mm cable, 11 kv indoor cable boxes for 3c x 300 sq mm cable, gi channel 100x50x6mm (gi) various size, gi angle iron 50 x 50 x 6 mm (gi) various size, gi flat 50 x 6 mm, gi flat 75 x 8 mm for earth mat in switchyard, earthing of s/stn. with pipe & earthing plate complete with machnary chamber, g.i pipe 40 mm dia 6 mtr. long for earthing set b class, premier synthetic insulating mat (class-b as per isi 15652:2006), pg clamps for panther conductor, gi nut & bolt off size, flood light led 240 watt (ip-67 rating), aluminium die cast body (make-, crompton, bajaj, phillips and havells only), 11 meters long pcc poles, un armoured copper control cable 2c x 6mm2, un armoured copper control cable 2c x 4mm2, un armoured copper control cable 7c x 2.5mm2, un armoured copper control cable 10c x 2.5mm2, un armoured copper control cable 3c x 4mm2, un armoured copper control cable 4c x 4mm2, un armoured copper control cable 6c x 4mm2, c-wedge connector for 0.2 sq. inch. panther conductor (nom. ai area, 200mm2), 33 kv polymeric disc insulators 70/90 kn b & s type, single tension fitting for 0.2 inch2 /150 mm2 acsr conductor, wooden cleat, ni-cd alkaline battery capacity (100ah) with static battery charger as, per nigam's specification., dry chemical type fire extinguisher (5 kgs), co2 type fire extinguisher (10 kgs), dry chemica
Tender For supply of 9 kva, 750/415/190 v ac 3 phase star star star step down distribution transformer for as per rdso spec no. rdso/pe/spec/tl/0158-2010 (rev1), type-1 [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status
Tender For supply of coil 5 ohm , resistance coil 10 ohm , reversing key , sonometer with weight , spherometer 1 mm pitch , viscosity apparatus , youngs modulus , vernier callipers ime type , metallic sphere with hook , zener diode characteristics apparatus , pn junction diode chartersics apparatus , transistor characterstics apparatus pnp and npn , study of logic gate apparatus , friction board apparatus , thermometer 220 f , fraction weight box , plier taparia , screw driver set multipurpose , transformer step up and step down , led 2 watt , inclined plane , milli ammeter , milli voltmeter , ohms law apparatus , retort stand with clamp and bose head , helical sprinf slinky , split cork , travelling microscope , spirit level small , overflow cane , one way key , two way key , four way key , jockey , constantan wire , magnesium wire , watch glass 3 inch , watch glass 2 inch , hanger with weight 50 gm , newton colour disc , spirit lamp , tornedo working model , archmedies principle working model , hand generator working model , solenoid engine working model , electric mlotor working model , magnetic induction working model , domestic circuit parallel working model , domestic circuit series working model , battery eliminator 2 amp , magnetic compass medium size , wire cutter stripper cutter , dry cell charger , rehostat 50 ohm , rehostat 100 ohm , telescope , battery 6 volt , 9 volt dry cell , battery 12 volt , galvanometer , voltmeter , ammeter , dc copper connection wire roll insulated , nicrome wire , simple torch , laser torch red , laser torch green , laboratory stop watch 60 sec timer , white screen for image formation , plane mirror mounted on wooden block 10 x 15 cm , compass magnet small , iron filling , thread roll , geomerical instrument box , paper pin box , thumb pin box , lens cleaner fluid , multimeter digital , ebonite rod , glass rod 20 to 25 cm , test tube , test tube stand , solar system model , soldering iron , solder flux , soder wire resin 100gm , paper tape , plain stickers or label pkt , electric apparatus chart , prism refraction chart , eye defect and correction chart , inertia of 3d body , reflection of convex mirror on different position , reflection of concave mirror on different position , human eye chart , symbols of components used in circuit diagram , flaming left and right hand rule , sound wave refraction and compression , carbon resistance band reading chart , dry cell part chart , solar system chart , albert einstein portrait , prafulla chandra roy portrait , chandrasekhara venkata raman portrait , homi jehangir bhabha portrait , jagadish chandra bose portrait , dr apj abdul kalam portrait , sir issac newton portrait , ammonium chloride 500 gm chemical , copper sulphate 500 gm chemical , zinc sulphate 500 gm chemical , zinc rod , spirit solution for spirit lamp 1 ltr , first aid kit , sitting stools , cupboard or almirah shelf , lab open rack
Tender For purchase of tanche - lab equipments for eee and ece department - purchase - lab equipments for eee department electronics lab, single phase to single phase cyclo converter kit single-phase bridge cycloconverter power devices: scr/triac based input supply: 230 v ac, 50 hz step-down isolation transformer 230 v / 12 v output: 12 15 v ac, frequency: 0 25 hz (adjustable),firing angle control circuit and frequency control circuit to be provided built-in resistive load, terminals to be brought on ms panel with necessary symbols and circuits, pwm based step down dc chopper using mosfet/igbt kitpwm based step-down dc chopper (buck converter) power device : power mosfet / igbt based switching circuit input supply : 24 v dc to 110 v dc or derived from 230 v ac mains through rectifier unit output voltage :(0 to vin) variable dc output current : up to 5 a dc maximum with suitable load resistor (r load) pwm duty cycle control provided pwm generation and control circuit inbuilt gate driver circuit provided, single phase single pulse / sinusoidal pwm inverter using mosfet/igbt kittype : single phase pwm inverter trainer power device : mosfet / igbt based inverter circuit input supply : 12 24 v dc output voltage : 30 v rms ac output phase : single phase output frequency : 0 50 hz variable output power : 100 w single pulse pwm operation sinusoidal pwm (spwm) operation variable frequency control pwm generation and firing control circuit inbuilt gate driver circuit provided test points provided for waveform observation and analysis built-in resistive load provision, on / off control of lamp using solid state relay kittype : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status, speed control of ac motor using vfd drive module with ac motortype : variable frequency drive (vfd) module input supply : 415 v ac, three phase, 50 hz output : three phase variable voltage and variable frequency ac output 1 hpthree phase squirrel cage induction motor415 v ac 50 hz &1440 rpm control technique : pwm / spwm based control frequency range : 0 50 hz variable digital display for frequency and operating parameters start / stop and forward / reverse control, acceleration and deceleration control facility powder coated ms control panel tabletop / floor mounted laboratory type setup clearly labelled circuit diagram and control switches proper insulated terminals and earthing arrangement, purchase - lab equipments for eee department electrical machines lab, three phase transformertype: three phase transformer, rating: 3 kva input voltage: 415 v ac, 3-phase, output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory usebench/floor, dc stepper motor drive kit with stepper motorinput supply : 230 v ac, 50 hz stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection., dc servo motor drive kit with servo motorinput supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive contr